EXAMPLE
:
Marked item (Graph 1), confirm with ENTER button. In the window - Signal selection choose the
required displayed value and confirm.
The first graph (Graph 1) is drawn with a thinner line and second graph (Graph 2) with a thicker
line. The selected value, the maximum and minimum displayed value is displayed in the bottom
part of the graph window on the left side and the current value is displayed on the right side of the
window. The graph timestamps are displayed in the line over these variables. The value of the
displayed time scale and device status is displayed in the upper part of the graph.
.
Graph window
Time scale
Time tag
Value monitoring by using
the cursor
The values of selected signals are stored in the memory with a given selected step size when
running the graph (F3-START). The maximum recording time is calculated from the step size.
Record continues after you restart the panel (if record was running). The period of time when there
is no corresponding record is filled with backslash lines. Graph record is indicated by a graph
symbol in device status bar. It is possible to switch to the another window during record and the
record runs normally in the background.
Start, Stop
Start, stop
of the record into the internal memory according to the
options set
Set
Graph options setting
Adjust the limits
–
set the cursor in the graph to real time. Graph will be
displayed in real time
Clear graph
–
deletes the data from the graph
Graph 1, 2
–
selection of the recorded signals
Time scale
–
size of the displayed section between two timestamps.
It can be changed by using arrows up and down in the graph window.
Sampling
–
period of updating the values of selected values
Record lenght
–
informs about the maximum record, that can fit into
memory at the current set sampling
Recording mode
–
determines, whether the oldest samples will be
overwritten or not after filling the storage memory
Cursor, Record
Record
–
displays the last recorded signal and allows real-time record
tracking
Cursor
–
allows graph analyzing by using the cursor
Shift
Cursor position change in the cursor mode