5.5 EXHAUST SYSTEM INSTALLATION (on request)
The generator is supplied an exhaust manifold, on which an overtemperature safety switch is installed.
Exhaust manifold
It is the responsibility of the installer to design and install a suitable exhaust system in order to avoid
water returning to the engine with any sea conditions and any inclination of the boat.
Connect the drain terminal with a water approved tubing and pass the drain system through the hole in the
generator bottom capsule.
Holes for exhaust system piping passage
The installer MUST have a basic knowledge of the requirements of marine generator installations,
safety systems and seawater cooling systems.
Incorrect installation and design of the exhaust line can cause severe damage to the generator,
potentially causing the boat to sink.