7
START AND STOP PROCEDURE
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
1
7. STARTING/SOPPING PROCEDURE
7.1 CHECKS TO BE CARRIED OUT BEFORE STARTING
Before starting, the following checks must be carried out:
1. Check for possible leaks from all the connections inside the sound-shield.
2. Make sure the cooling water is discharging properly, outboard from the exhaust outlet.
3. Make certain that the generator is mounted securely.
4. Listen for unusual sounds and vibrations.
Once these checks have been carried out and the correct operation has been verified, the upper guards of the
capsule can be closed, making sure to make the 2 halves fit together correctly and to lock them in place using
the appropriate silicone rubber bands.
7.2 START-UP PROCEDURE
Button to start the generator.
Press and hold the button for approximately 10 seconds. This time is required to start the pre-heat and then
the generator. Release the button only when the generator starts.
Control panel
WARNING! All AC loads must be switched off before starting. This precaution will prevent damage
caused by unanticipated operation of AC machinery and will prevent a cold engine from stalling.
NOTE
If a start attempt is aborted, reset the circuit by pressing the “STOP” button.
Apply a light load to the generator and allow the engine to warm up to operating temperature before
applying heavy loads.