9
GENERAL SAFETY INFORMATION
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
1
9. GENERAL SAFETY INFORMATION
Read these safety instructions carefully. Most accidents are caused by failure to follow fundamental rules and
precautions. Know when dangerous conditions exist and take the necessary precautions to protect yourself,
your personnel and your machinery.
The following safety instructions are in compliance with the American Boat and Yacht Council (ABYC)
standards.
9.1 PREVENT ELECTRIC SHOCK
Do not touch AC electrical connections while engine is running, or when connected to
shore power. Lethal voltage is present at these connections!
Do not operate this machinery without electrical enclosures and covers in place.
Shut-off electrical power before accessing electrical equipment.
Use insulated mats whenever working on electrical equipment.
Make sure your clothing and skin are dry, not damp (particularly shoes) when handling electrical
equipment.
Remove wristwatch and all jewelry when working on electrical equipment.
Do not connect utility shore power to vessel’s AC circuits, except through a ship-to-shore double throw
transfer switch. Damage to vessel’s AC generator may result if this procedure is not followed.
Electrical shock results from handling a charged capacitor. Discharge capacitor by shorting terminals
together with an insulated tool.
9.2 PREVENT FIRE
Do not touch hot engine parts or exhaust system components. A running engine gest very hot!
Steam can cause injury or death!
In case of an engine overheat, allow the engine to cool before touching the engine or checking the
coolant.
Prevent flash fires. Do not smoke or permit flames or sparks to occur near the fuel line, filter, fuel pump,
or other potential sources of spilled fuel or fuel vapors. Use a suitable container to catch all fuel when
removing the fuel line or fuel filters.
Keep the compartment and the engine / generator clean and free of debris to minimize the chances of
fire. Wipe up all spilled fuel and engine oil.
Be aware – diesel fuel will burn.
9.3 PREVENT EXPLOSIONS
Explosion from fuel vapours can cause injury or death!
Follow re-fueling safety instructions. Keep the vessel’s hatches closed when fueling. Open and ventilate
cabin after fueling. Check below for fumes / vapor before running the blower. Run the blower for four
minutes before starting your engine.
All fuel vapors are highly explosive. Use extreme care when handling and storing fuels. Store fuel in a
well-ventilated area away from spark-producing equipment and out of the reach of children.
Do not fill the fuel tank(s) while the engine is running.
Shut off the fuel service valve at the engine when servicing the fuel system. Take care in catching any
fuel that might spill. DO NOT allow any smoking, open flames, or other sources of fire near the fuel
system or engine when servicing. Ensure proper ventilation exists when servicing the fuel system.
Do not alter or modify the fuel system.
Be sure all fuel supplies have a positive shutoff valve.
Be certain fuel line fittings are adequately tightened and free of leaks.
Make sure a fire extinguisher is installed nearby and is properly maintained. Be familiar with its proper
use. Extinguishers rated ABC by the NFPA are appropriate for all applications encountered in this
environment.