10
MAINTENANCE
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
2
2. Access to the generator is allowed
only to authorized personnel
.
3. Do not modify or tamper with the generator structure without a written statement to the company
VTE
S.r.l.
.
4. Record the maintenance operations on the “SHEET OF MAINTENANCE INTERVENTIONS” attached
to the manual, which shows the date, group of the generator, type of work and signature of the person
who performed the operation. Keep the updated table close to the generator.
Any maintenance operation should refer to what is written in this chapter.
10.2 ORDINARY MAINTENANCE
10.2.1 Maintenance status
MAINTENANCE STATUS AND maintenance operations are the exclusive responsibility of the maintainers,
each for their skills, as defined in the Cap. 3 "OPERATOR”:
The procedure provides
for insulation from electrical energy:
-press the “STOP” key on the remote control to stop the generator.
– the service technician disconnects the battery cables using suitable Personal Protective Equipment and
electrically insulated tools.
Before servicing the generator, use protective gloves and always wait until all components of the generator
are at room temperature (< 50°C).
The maintainer, once the maintenance work has been completed and before returning the generator
to operation, must always check that:
–
any parts replaced and/or tools used have been removed from the generator.
–
check that all the guards removed during the operation are refitted, correctly positioned and
secure with their elastic bands.
Only at the end of the maintenance intervention and after having made the appropriate checks can the
operating conditions be restored.
10.2.2 General safety warnings
Generator and also operator safety depend on the regularly scheduled maintenance procedures, in
accordance with the Manufacturer instructions. Maintenance workers must:
– observe the limits of their qualifications (mechanical or electrical);
– in accordance with their own competencies, follow the User and Maintenance Manual procedures and
the warnings associated with it;
– respect the indicated times and frequency of scheduled maintenance procedures.
GENERAL WARNINGS applicable to any situation:
– risk of electrocution by direct contact with power supply terminal boards and junction boxes in the electrical
system;
– it is prohibited to open terminal boards and junction boxes when the generator is running;
Carefully inspect the generator before starting it again and check that all guards are correctly refitted
and secure.