11
TYPES OF RISKS AND SAFETY PICTOGRAMS INCLUDED
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
1
11. TYPES OF RISKS AND SAFETY PICTOGRAMS INCLUDED
11.1 RISKS OF A MECHANICAL NATURE
This paragraph describes the mechanical risks that can arise during installation or maintenance operations on
the generator, the risks that they can generate and the protections that have been adopted. Normally these
risks do not affect the operator since protections are enabled during ordinary operation and the risks have
been eliminated or reduced.
During maintenance, the risks are partially reduced if the safe method of intervention is implemented by placing
the generator in maintenance state. Any special circumstances will be indicated in the following points. When
carrying out repairs or other extraordinary work, the risks outlined in the following points must be considered.
11.1.1 Generator stability
The generator correctly installed has not instability or overturning risks.
Observe the instructions given in par. 5.2 “Fixing the generator” for proper installation.
11.1.2 Breakage dangers during the functioning of the generator
The safety of the generator depends proportionally by the respect of the times and the modes required for the
periodic check, the maintenance, the cleaning and the replacement of the worn parts.
WARNING! It is necessary to:
– observe the envisioned timeframes (see par. 10.2.7 “Ordinary maintenance table”);
– use original spare parts;
- follow the procedures indicated in the User and Maintenance Manual and/or by the manufacturer of
the specific spare parts;
– assign skilled staff to perform the procedures (maintainers).
Failure to do so relieves the Manufacturer of all liability.
No mechanical parts are exposed to corrosion or stress that could lead to dangerous.
WARNING! IT IS FORBIDDEN TO:
place objects on the generator.
use the soundproofing capsule as a support or work surface.
11.1.3 Dangers and risks caused by flying objects
The parts that can be a source of danger are normally protected by protective carter, in order to guarantee
safety conditions.
Lack of maintenance or failure to observe the maintenance schedules indicated by the Manufacturer may
cause the fluid circuit elements (pipes, fittings, etc.) to wear early and also cause fluid leakage.
Sudden leaks from the fluidic circuits can damage the generator and compromise its operation.