![Vivax Metrotech vLoc3 RTK-Pro Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/vivax-metrotech/vloc3-rtk-pro/vloc3-rtk-pro_user-handbook-manual_1038513069.webp)
™
Page 61 of 67
6 Using the Accessories
6.3 Using the vLoc3 RTK-Pro Remote Antenna
The remote stethoscope antenna can be used to help trace a particular cable on a cable tray or where cables are bunched
together.
Methods:
1. Connect a signal to the cable to be identified. The remote stethoscope functions have an operational frequency range of
512Hz up to 200 kHz, but low frequencies should be a preference in this application as they are less likely to leak or bleed
over to other cables.
2. When cables are earth bonded together and the cross bonds cannot be removed. the best method of signal application is
to use the signal clamp. This is because the signal clamp applies a signal to the target cable and shares an equal amount
with other cross bonded cables.
3. When using the signal clamp, it is best if both ends of the target cable are grounded. Apply the clamp below the ground
point. Applying the clamp above the ground point will prevent the signal finding the return path through the ground, so this
is not advised.
4. If it is not possible to use a transmitter signal clamp, and you have confirmation that the cable is out of service, use a direct
connection lead to make an electrical connection to the cable. Removing any cross bonding between cables prevents the
signal traveling along commonly bonded cables.
5. It is best not to use the Induction method as the signal will appear on all cables in the area of the transmitter.
6. Connect the remote stethoscope antenna to the accessory input of the receiver. The correct settings and user interface will
be automatically selected.