Troubleshooting
Stand 5/12
Page 50 of 57
6.2.9 Motive rare to see
Possible cause:
Check/fix:
Density of dots too low
For newly created motive dot pitch has been chosen
may be too high and thus the density of dots is too low.
In addition engraved text can be used as a reference for
good visibility. If text is OK, but only the motive is
weakly to see, just create a new point cloud of the
motive
Diode performance declines
Increase power for pumping diodes. Please check the
allowed values with service technicians.
If power can not be increased, exchange diode module.
6.3 Changing the lens
If as source of error the lens is identified e.g. by mechanical damage, the exchange has to be
done by a service technician in any case!
The exchange requires a new calibration of the system, which can not be made by you.
6.4 Replacing the laser diode module
The exchange of a laser diode module - See also 6.2.9 - can possibly be done by yourself
under certain circumstances. To do this please contact a service technician who can clarify in
consultation with you, whether the exchange can be done by yourself.