3.6 Laser system switches
The main switch for the power supply is located at the backside of the system.
On the front side below the safety door the following switch and indicator are located:
(1) ACK white
For service personnel only. Without function during normal operation
(2) Cover white
Unlock the security door to load and unload the machine. During the laser process,
the button has no function to avoid accidentally stopped processes.
If the button lights up no laser process is active and the door can be opened safely.
To open the door, press and hold the key and open the door after the safety lock has
been resolved.
(3) Fault red
Signals error in the security, such as the pressed emergency-stop button, and lights
up when you turn on the machine as functional testing.
If everything is OK the light is switched off a few seconds after pressing the "power"
button.
(4) Stop red
For service personnel only. Without function during normal operation.
(5) Start green
For service personnel only. Without function during normal operation..
(6) Key switch Mode
For service personnel only. Without function during normal operation.
(7) Power green
Safety switches, switches on laser and engines.
(8) Emergency stop yellow/red
To immediately turn off the axles and the laser head in case of an emergency