5.3 Lubricate motor axles
5.3.1 Guide rails
The rails of all axes can be lubricated by the gap between the black lips.
The sealing lips even include a Teflon component and require no special maintenance.
From the factory all guided rails and waves are lubricated with the sodium SOAP grease
GP00/000F-20 DIN 51 502. This fat also s available from us as a spare part.
To smear the guide rails open the sealing lips tightly and apply some fat - approximately in
the middle of the rail - on the guide rail with your fingertip.
Each axle has 2 channels, so a total of 6 guide rails has to be lubricated.
The fat is distributed later manually by controlled movement (2-3 times) across the entire
range of motion after switching on the machine.
5.3.2 X-axis
The lubrication nipple of x-axis can be reached from the outside of the machine.
Pull off the black plastic cap and lubricate the axes using the lubrication nipple which have
been exposed. Replace the plastic cap after finishing the procedure.
.
Figure 1:
(1)
Plastic cap.
Underneath the cap the nipple for lubrication is located.
.