9/60 NT00000658-TEDH-V-F400-ECOWATT-AN-210609
3.3.4 Adaptation plate : TCDZ 05
G
E
ØD
T
The adaptation plate allows connecting roof fan
to a circular duct. Since it is designed to make the
air connection, it is not supposed to withstand roof
fan weight. This is incompatible with the use of the
energy saver flap TCDZ 03 and the roof adapter
with sound attenuator TCDZ 09.
Model
Accessory
size
Dimensions (mm)
Weight
(kg)
G
E
T
ØD
355/400
Size 2
478
450
50
315
1,8
355/400
Size 2
478
450
65
355
1,5
355/400
Size 2
478
450
80
400
1,2
355/400
Size 2
478
450
80
450*
0,8
450/500
Size 3
598
570
80
400
3,6
450/500
Size 3
598
570
80
450
3,1
450/500
Size 3
598
570
80
500
2,5
450/500
Size 3
598
570
80
560*
1,7
630
Size 4
698
668
80
450
5,1
630
Size 4
698
668
80
500
4,5
630
Size 4
698
668
80
560
3,7
630
Size 4
698
668
90
630
2,7
710
Size 5
866
830
80
560
11,8
710
Size 5
866
830
90
630
10,3
710
Size 5
866
830
120
710
8,3
* These adaptation plates cannot be mounted in the following accessories: TCDZ 02, 04, 07 and 08.
3.3.5 Tipping-up kit: TCDZ 06
This kit allows safely swinging the roof fan for cleaning operations. It is placed on the embedding frames
TCDZ 02, roof adapters TCDZ 04, TCDZ 07 or TCDZ 09 and can be placed on top of the adaptation
plates TCDZ 05 or the energy saver flap TCDZ 03.
hinge
lug piece
Safety bar
Chain
•
Make sure that there is a sufficient height
between the floor and the roof fan plate so
that the roof fan does not touch the floor/
ground when it swings.
• Make sure that the power cables lengths are
sufficiently long to allow swinging the ma
-
chine without stressing them.
Make sure that the support is correctly attached
to the floor and can withstand the shearing stress
due to the swinging of the roof fan :
•
Position the hinge and fasten it with the 2 flat
nuts supplied.
• Tie up a chain extremity to the lug piece with
the HM18x16 bolt provided.
• Position the undrilled side of the safety bar
in the lug piece and fit the assembly on the
support.
•
Fasten the lug piece with the 2 flat nuts sup
-