14/60 NT00000658-TEDH-V-F400-ECOWATT-AN-210609
3.6
Mounting the roof fan deflectors
3.6.1 Vertical discharge kit KRVT
Allows transforming a horizontal roof fan TEDH F400 ECOWATT
®
into a vertical roof fan TEDV F400
ECOWATT
®
.
It is recommended to wear protective gloves to handle the various elements.
Self drilling screw Ø4.2
Vertical
deflector
Size 355 and 400 :
• Remove the caps.
•
Clip the deflector on the
fastening screw heads of
the mesh protection.
•
Fix the deflector with the
4.2mm dia. self-drilling
screws supplied (wrench
size. 8).
Deflector
edge
Deflector
surface
Size 450 up to 710 :
•
Lay the deflector surface
on the floor.
• Insert the edge in the fold
by aligning the tenon of the
surface with the opening of
the edge.
• Raise the edge.
• Do the same with the other
edge.
•
Remove the caps (see fi
-
gure, sizes 355-500).
•
Clip the deflector to the
fastening screw heads of
the mesh protection.
•
Attach the deflector with
the 4.2 mm dia. self-drilling
screws supplied (wrench
size. 8).