Checking and cleaning the flue gas heat exchanger
1.
Pull the plug from boiler water tem-
perature sensor
B
and tempera-
ture limiter
C
.
2.
Release plug-in connector clip
A
from the connecting pipe and
release fitting
D
.
3.
Pull flue gas heat exchanger
E
forward to remove.
4.
Clean the flue gas heat exchanger,
if required, with compressed air or
with a soapy solution.
Flush with clean water.
Further details regarding the individual steps
(cont.)
34
Commissioning, inspection, maintenance