Checking the outlet temperature sensor
A
Outlet temperature sensor
1.
Pull the leads off the outlet tem-
perature sensor.
2.
Check the sensor resistance and
compare it with the curve.
3.
Replace the sensor in case of
severe deviation.
Danger
The outlet temperature sen-
sor is immersed in the DHW
(risk of scalding).
Drain the DHW side of the
boiler before replacing the
sensor.
Repairs
(cont.)
93
Troubleshooting
5592
817