Checking the ignition and ionisation electrodes
1.
Check ignition electrodes
A
and
ionisation electrode
B
for wear
and contamination.
2.
Clean the ignition electrodes with a
small brush or emery paper.
3.
Check the electrode gaps.
Replace the electrodes, if the gaps
are not as specified or the electro-
des are damaged. Tighten the elec-
trode fixing screws
C
with 2 Nm.
Further details regarding the individual steps
(cont.)
35
Commissioning, inspection, maintenance
5592
817
GB
Service