B
Vitotrol 100 UTD (only for con-
stant temperature control units)
C
Vitotrol 100 UTA (only for constant
temperature control units)
Plug 230 V~
fÖ
Power supply
Danger
Incorrect core terminations
can cause severe injuries
and damage to the equip-
ment.
Never
interchange cores
"L1" and "N".
&
Install an isolator in the power
supply line that simultaneously
separates all non-earthed con-
ductors from the mains with at
least 3 mm contact separation.
Remove the existing cable
grommet when using larger
cross-sections (up to
7
14 mm).
Secure the cable with cable
grommet
F
(see page 14) inte-
grated into the casing base.
&
Max. fuse rating 16 A.
lH
Power supply of accessories
Where the boiler is installed in wet
areas, the connection to the
power supply of accessories out-
side the wet area must not be car-
ried out at the control unit. The
power supply connection for
accessories can be made immedi-
ately at the control unit, if the boil-
er is installed outside wet areas.
This connection is controlled
directly with the system ON/OFF
switch (max. 3 A)
&
Vitotrol 100 UTA
&
Vitotrol 100 UTD
Low voltage plugs
!
Outside temperature sensor (only
for weather-compensated control
units)
Installation:
&
North or north-western wall, 2 to
2.5 m above ground level; in
multi-storey buildings, in the
upper half of the second floor
&
Not above windows, doors or
ventilation outlets
&
Not immediately below balco-
nies or gutters
&
Never render over
&
Cable length max. 35 m with a
cross-section of 1.5 mm
2
?
Flow temperature sensor for low
loss header (accessories)
aVG
KM BUS subscriber (acces-
sories)
&
Vitotrol 200 or 300 remote con-
trol (only for weather-compen-
sated control units)
&
Vitocom 100
&
Extension kit for one heating
circuit with mixer (only for
weather-compensated control
units)
&
External extension H1 or H2
Electrical connections
(cont.)
14
Installation sequence
5592
817
GB
Содержание VITOPEND 200
Страница 9: ...Installing the boiler and making all connections 9 Installation sequence 5592 817 GB Installation...
Страница 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Страница 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Страница 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Страница 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Страница 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Страница 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Страница 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Страница 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Страница 130: ...130 5592 817 GB...
Страница 131: ...131 5592 817 GB...