Setting the maximum output
You can limit the maximum output for
heating operation
. The limit is set via the
modulation range.
Note
The value to be entered is the approximate percentage of the max. rated output:
100 % corresponds to 29 kW rated output.
1.
Start the boiler.
2.
K
+
F
press simultaneously:
"
100
" flashes (equals
29 kW output) and "
A
"
is displayed.
On weather-compen-
sated control units, the
display additionally
shows "
Max. output
".
a
/
b
for the required output
("
34
" equals 10.5 kW out-
put).
d
to confirm.
3.
Record the setting for the maxi-
mum output on the additional type
plate supplied with the "technical
documentation". Affix the type
plate next to the type plate on top
of the boiler.
Further details regarding the individual steps
(cont.)
29
Commissioning, inspection, maintenance
5592
817
GB
Service
Содержание VITOPEND 200
Страница 9: ...Installing the boiler and making all connections 9 Installation sequence 5592 817 GB Installation...
Страница 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Страница 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Страница 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Страница 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Страница 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Страница 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Страница 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Страница 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Страница 130: ...130 5592 817 GB...
Страница 131: ...131 5592 817 GB...