Checking and cleaning the burner
1.
Switch OFF the ON/OFF switch
on control unit
E
and the power
supply.
2.
Close the gas shut-off valve and
safeguard against reopening.
3.
Release and remove cover
plate
H
.
4.
Release control unit
E
and pivot
downwards.
5.
Unscrew combustion chamber
frame
G
.
6.
Unscrew combustion chamber
cover
F
.
7.
Pull plug-in connector
B
apart.
Further details regarding the individual steps