Fault
code
on the
display
Const.
weath.-
comp.
System char-
acteristics
Cause
Measures
92
X
X
Control mode
Collector
temperature
sensor
shorted out;
connects to
the Vitosolic
at S1
Check the sensor
at the Vitosolic.
93
X
X
Control mode
Cylinder
temperature
sensor
shorted out;
connects to
the Vitosolic
at S3
Check the sensor
at the Vitosolic.
94
X
X
Control mode
Temperature
sensor
shorted out;
connects to
the Vitosolic
at S2
Check the sensor
at the Vitosolic.
9A
X
X
Control mode
Collector
temperature
sensor lead
broken; con-
nects to the
Vitosolic at
S1
Check the sensor
at the Vitosolic.
9b
X
X
Control mode
Cylinder
temperature
sensor lead
broken; con-
nects to the
Vitosolic at
S3
Check the sensor
at the Vitosolic.
Fault codes
(cont.)
73
Troubleshooting
5692
673
GB