Overview
Coding
Coding in the delivered condition
Possible change
System design
00:1
System version 1:
1 heating circuit without
mixer A1, without DHW
heating
00:2
System version 1:
1 heating circuit without
mixer A1, with DHW heat-
ing
00:3
System version 5:
1 mixer circuit M2, with-
out DHW heating
00:4
System version 5:
1 mixer circuit M2, with
DHW heating
00:5
System version 2, 3, 4:
1 heating circuit without
mixer A1 and 1 mixer cir-
cuit M2, without DHW
heating
00:6
System version 2, 3, 4:
1 heating circuit without
mixer A1 and 1 mixer cir-
cuit M2, with DHW heat-
ing
Max. boiler water temp.
06:...
Maximum limit of the
boiler water tempera-
ture, defaulted by the
boiler coding card
06:20
to
06:127
Maximum limit of the boil-
er water temperature
within the ranges de-
faulted by the boiler
Venting/filling
2F:0
Venting program/fill pro-
gram disabled
2F:1
Venting program enabled
2F:2
Fill program enabled
Code 1
(cont.)
37
Coding
5692
673
GB
Содержание VITODENS 300-W
Страница 106: ...aND Water pressure sensor a Modulation coil Connection and wiring diagram internal cont 106 Designs 5692 673 GB...
Страница 107: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 107 Designs 5692 673 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 673 GB...
Страница 112: ...Parts lists cont 112 Parts lists 5692 673 GB...
Страница 113: ...Parts lists cont 113 Parts lists 5692 673 GB...
Страница 114: ...Parts lists cont 114 Parts lists 5692 673 GB...
Страница 121: ...121 5692 673 GB...
Страница 122: ...122 5692 673 GB...
Страница 123: ...123 5692 673 GB...