Coding in the delivered condition
Possible change
Fb:30
Duration for raising the
set boiler water tem-
perature or the set flow
temperature (see cod-
ing address "FA")
60 min. See example on
page 101 (only for
weather-compensated
control units).
Fb:0
to
Fb:150
Duration adjustable from
0 to 300 min;
1 step
≙
2 min
Resetting codes to their delivered condition
Constant temperature control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
press.
Weather-compensated control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
"
Factory set? Yes
"
appears.
3.
d
to confirm
or
a
/
b
to select "
Factory set?
No
".
Code 2
(cont.)
60
Coding
5692
673
GB
Содержание VITODENS 300-W
Страница 106: ...aND Water pressure sensor a Modulation coil Connection and wiring diagram internal cont 106 Designs 5692 673 GB...
Страница 107: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 107 Designs 5692 673 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 673 GB...
Страница 112: ...Parts lists cont 112 Parts lists 5692 673 GB...
Страница 113: ...Parts lists cont 113 Parts lists 5692 673 GB...
Страница 114: ...Parts lists cont 114 Parts lists 5692 673 GB...
Страница 121: ...121 5692 673 GB...
Страница 122: ...122 5692 673 GB...
Страница 123: ...123 5692 673 GB...