Weather-compensated control
unit:
K
+
d
press simultaneously:
"
Relay test
" and then
"
Base load
" is shown.
4.
Check the CO
2
content. Should the
actual value deviate from the
above ranges by more than 1 %,
implement steps from page 22.
5.
Enter actual values into the service
report.
6.
Adjust the upper output.
Constant temperature control
unit:
a
press:
"
2
" is shown.
Weather-compensated control
unit:
a
press:
"
Full load
" is shown.
7.
Check the CO
2
content. Should the
actual value deviate from the
above ranges by more than 1 %,
implement steps from page 22.
8.
After testing, press
d
.
9.
Enter actual values into the service
report.
Matching the control unit to the heating system
The control unit must be matched to the equipment level of the system. Various
system components are recognised automatically by the control unit and the
relevant codes are adjusted automatically.
&
For the selection of an appropriate design, see the following diagrams.
&
For coding steps, see page 36.
Further details regarding the individual steps
(cont.)
23
Commissioning, inspection, maintenance
5692
673
GB
Содержание VITODENS 300-W
Страница 106: ...aND Water pressure sensor a Modulation coil Connection and wiring diagram internal cont 106 Designs 5692 673 GB...
Страница 107: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 107 Designs 5692 673 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 673 GB...
Страница 112: ...Parts lists cont 112 Parts lists 5692 673 GB...
Страница 113: ...Parts lists cont 113 Parts lists 5692 673 GB...
Страница 114: ...Parts lists cont 114 Parts lists 5692 673 GB...
Страница 121: ...121 5692 673 GB...
Страница 122: ...122 5692 673 GB...
Страница 123: ...123 5692 673 GB...