Display screen
Explanation
Mixer OPEN
Mixer extension
Mixer CLOSE
Mixer extension
Output int. ON
Output
sK
internal extension
Heating circuit pump
A1 ON
External extension H1
Cylinder pump ON
External extension H1
DHW circ. pump ON
External extension H1
Central fault ON
External extension H1
Constant temperature control unit
Press the following keys:
1.
K
+
d
simultaneously for
approx. 2 s.
2.
a
/
b
for the required relay out-
put.
3.
d
Relay test is completed.
The following relay outputs can be controlled subject to system design:
Display screen
Explanation
1
Burner modulation base load
2
Burner modulation full load
3
Internal pump / output 20 "ON"
10
Output
sK
internal extension
11
Heating circuit pump A1 External extension H1
12
Cylinder primary pump External extension H1
14
Central fault message External extension H1
Scanning operating conditions and sensors
Weather-compensated control unit
Press the following keys:
1.
c
"Select heating circuit" is
displayed.
2.
d
to confirm; wait approx.
4 s.
3.
c
press again.
4.
a
/
b
for the required operating
condition.
5.
d
Scanning is completed.
Checking outputs (relay test)
(cont.)
65
Service scans
5692
761
GB
Содержание Vitodens 200-W WB2B Series
Страница 105: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 105 Designs 5692 761 GB...
Страница 109: ...Parts lists cont 109 Parts lists 5692 761 GB...
Страница 110: ...Parts lists cont 110 Parts lists 5692 761 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 761 GB...
Страница 118: ...118 5692 761 GB...
Страница 119: ...119 5692 761 GB...