Coding in the delivered condition
Possible change
67:40
With the Vitosolic: Third
set DHW temperature =
40 °C
67:0
Without third set DHW
temperature
67:1
to
67:60
Third set DHW tempera-
ture adjustable from 1 to
60 °C (subject to the set-
ting of coding address
"56")
6F:...
Maximum output for
DHW heating in %, de-
faulted by the boiler
coding card
6F:0
to
6F:100
Max. output during DHW
heating adjustable from 0
to 100 %
71:0
DHW circulation pump:
"ON" in accordance
with the time program
(only for weather-com-
pensated control units)
71:1
"OFF" during DHW heat-
ing to the first set value
71:2
"ON" during DHW heat-
ing to the first set value
72:0
DHW circulation pump:
"ON" in accordance
with the time program
(only for weather-com-
pensated control units)
72:1
"OFF" during DHW heat-
ing to the second set
value
72:2
"ON" during DHW heat-
ing to the second set
value
73:0
DHW circulation pump:
"ON" in accordance
with the time program
(only for weather-com-
pensated control units)
73:1
to
73:6
during the time program
"ON" 1x/hour for 5 min
"ON" up to 6x/hour for
5 min
73:7
permanently "ON"
General
76:0
Without LON communi-
cation module (only for
weather-compensated
control units)
76:1
With LON communication
module; automatic recog-
nition
76:2
With KM BUS/cascade
communication module;
automatic recognition
77 :1
LON subscriber number
(only for weather-com-
pensated control units)
77 :2
to
77 :99
LON subscriber number,
adjustable from 1 to 99
(see page 32).
Note
Allocate each number
only
once.
Code 2
(cont.)
47
Coding
5692
761
GB
Содержание Vitodens 200-W WB2B Series
Страница 105: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 105 Designs 5692 761 GB...
Страница 109: ...Parts lists cont 109 Parts lists 5692 761 GB...
Страница 110: ...Parts lists cont 110 Parts lists 5692 761 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 761 GB...
Страница 118: ...118 5692 761 GB...