XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome
Installation
••••
9
g. Insert each labeled Crimp Connector into its respective labeled 23-pin Connector position (A, B, C,
D….etc.). Verify that each is firmly seated. If it is desired to use the Low Pressure Switch dry contact
outputs to trigger an internal alarm in the Camera Dome, use the following steps:
I.
Cut two (2) strips of 18 AWG wire about 1.5 in. (38 mm) in length and prepare each as
previously described in the cable preparation steps.
II.
Attach a Crimp Connector to each end of each wire and fasten with the previously described
Crimp Tool.
III.
Connect one wire from the “Low Pressure In (L)” pin to the “Alarm Input 1 (U)” pin. Connect
the remaining wire from the “Low Pressure Out (M)” pin to the “VSSA Ground (F)” pin. Verify
that each Crimp Connector is firmly seated into its respective pin.
h. Pull the Strain Relief Fitting back up the cable and screw it firmly into the base of the 23-pin Connector
Assembly.
i.
Gather all the cables at the other end of the Strain Relief Fitting into a bundle and tighten the two (2)
Strain Relief Fitting screws until the cables are snugly captured.
j.
Pull the Shrink Wrap Tubing back up the cable and push it over the Strain Relief Fitting until it meets
the base of the 23-pin Connector.
k. Using a heat gun or other directional heat source, heat the Shrink Wrap Tubing until it shrinks over the
23-pin Connector Assembly and cables.
l.
Assembling the connector is complete, proceed to the Final Assembly sub-section.
Caution: Overheating the Shrink Wrap Tubing can result in damage to the tubing and the entire 23-pin
Connector Assembly.
Final Assembly
23. Remove the Service Cover from the front of the Wall Mount by removing the four (4) captive screws.
24. Route the 23-pin Connector Assembly through the back of the Wall Mount and out the end of the Wall
Mount in excess of about 2 in. (51 mm). If cables were previously routed through the Access Hole in
previous steps, ignore this step, as the 23-pin Connector Assembly is already routed through the Wall
Mount.
25. Inspect the top of the Housing Assembly and verify that there is no debris on the gasket area. If there is,
wipe this surface clean with a cloth.
26. Lift the top of the Housing Assembly up to the Wall Mount’s Pressurized Housing Mounting Flange. Align
the two (2) sets of four (4) mounting holes so that the Fill Valve is located closest to the Service Opening
(slightly off to the right side, facing forward).
Note: Failure to correctly orient the Housing can cause difficulty in future servicing.
27. Insert the four (4) provided ¼-20 x 5/8 in. (16 mm) long Hex Head Screws through the provided ¼ in (6
mm) Lock Washers and into the mounting holes. Tighten all screws securely with a 5/8 in. (16 mm)
Socket Wrench. Carefully release the Housing Assembly and verify that the mount can support the weight
load.
28. With the Housing Assembly attached to the Wall Mount, locate the 23-pin Connector Assembly through
the Service Opening.
29. Insert the 23-pin Connector Assembly into the mating 23-pin connector on the top of the Housing
Assembly. Turn it until it drops down into the keyed slot and twist it clockwise ¼ turn to lock it.
30. Attach the previously removed Service Cover to the Service Opening using the four (4) captive screws.
31. Installation is complete. Refer to the Surveyor2000 Installation & Operation Manual for details on
configuration and operation.
Содержание surveyor 2000 XX004
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 28: ...18 Maintenance XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome NOTES ...
Страница 30: ...20 Shipping Instructions XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome NOTES ...