XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome
Maintenance
••••
17
Maintenance
The Pressurized Housing requires no scheduled maintenance; however, the Lower Dome requires occasional
cleaning.
Care and Cleaning of Clear Acrylic Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean dry pressurized air.
3. If spots, streaks or stains appear on the exterior, they can be removed with a solution of mild soap or
isopropyl alcohol and water using a lint-free soft paper towel. Dry with clean, dry pressurized air.
4. Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft
cleaning cloth.
Caution: Excessive rubbing of the Lower Dome surface can cause permanent scratches.
5. Clean all surfaces with any soft cleaning cloth and a mild glass cleanser suitable for acrylic plastic.
Fuse Replacement
A fuse (F2) is located on the Auxiliary Fan & Heater Interface Board. When necessary, replace it with the
following Fuse value and type:
F2: 5x20 mm, 4.0 amp, 250 volt, slo-blo