XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome
Installation
••••
3
Installation
Installation is a simple process. Choose the installation type based on the mounting configuration. All
mounting hardware (except for actual wall screws and pipe) is provided. When unpacking the Pressurized
Housing be sure to save the Carton Insert with the Hole to assist in assembly. In addition, the provided
Accessory Kit could contain either a discrete 23-pin connector with crimp pins or a prefabricated 23-pin cable
assembly. Use the applicable sub-section to install the correct connector type included.
Wall Mount Method
Use this method to install, wire and
configure a unit with a Vicon Wall Mount.
Refer to Figure 2.
Installing the Wall Mount
1. Select a suitable mounting location
and verify there is sufficient cable to
reach the end of the Wall Mount.
Caution: Mount only to vertical
structures with sufficient
strength and as vertically
plumb as possible.
2. Mark and drill mounting holes in the
surface using the Wall Mount Flange
as a template. Drill through-holes for
bolts or pilot holes for Lag Screws.
Note: Verify there are no obstacles behind
the surface before drilling.
3. Place a bead of Silicone Sealant
around the Wall Mount Mounting Flange, press it to the surface and line up the Flange holes with drilled
holes. Install the appropriate 3/8 in. (9.5 mm) stainless steel hardware and fasten snugly.
4. Place a bead of Sealant around the Flange to Wall seam.
5. If routing the cables on the outside of the Mount and through its Access Hole, use the following steps:
a. Remove the plastic Plug from the Mount’s Access Hole.
b. Remove the Mounting Nut from the provided Liquid Tight Fitting.
c. Insert the Liquid Tight Fitting into the Access Hole, install and tighten the Nut securely.
d. Route the cables through a section of standard 0.75 in. (19 mm) Conduit Pipe. If Conduit Pipe is used
throughout this installation, ignore this step.
e. Route the Conduit Pipe from the outside of the Mount into, and just through, the Liquid Tight Fitting.
Tighten the Seal Nut to compress the Gland around the Conduit Pipe. Place a bead of Sealant around
the Conduit Pipe to Gland seam.
Note: Routing an excessive length of Conduit Pipe through the Liquid Tight Fitting can cause difficulty in
routing the cables through the Mount.
f. Pull the cables through the Liquid Tight Fitting and out the end of the Mount in excess of about 2 in.
(51 mm).
Figure 2
Wall Mount Installation