5
15. Lift the Housing Assembly out of the carton, flip it over and shake it to remove any debris. Place it back in
the carton.
16. Verfiy that the O-ring in the groove of the Housing Assembly’s seal surface is properly seated, free of
debris and glistening with vacuum grease. If not, seat the O-ring in the groove, remove any debris and rub
additional vacuum grease on it.
17. Place the Trim Ring/Lower Dome Assembly on the Housing Assembly’s seal surface and align the eight
(8) Housing holes with the eight (8) Trim Ring/Lower Dome holes. Install the eight (8) screws and tighten
only with a torque wrench set for 15 in. lb (170 N cm) of force. Use an alternating (star) pattern to tighten
all the screws.