8
••••
Installation
XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome
Wiring and Assembling the 23-pin Connector
(If the discrete 23-pin connector with crimp pins was provided)
22. Assemble the 23-pin Connector
as shown in Figure 7.
a. Identify the cables required
for attaching to the 23-pin
Connector. There should be
a minimum of three (3),
power (22 to 28 VAC),
control (RS-422/485) and
video (RG-59 or
equivalent). There could be
optional cables for Alarm
Inputs, the Relay Output
(jacketed twisted pair) or a
low pressure indicator.
b. Route all cables through the
provided 2 in. (51 mm)
length of Shrink Wrap
Tubing and push the tubing
a few feet down the cable
bundle.
c. Route all cables through the
provided connector Strain
Relief Fitting and push the
connector near the Shrink
Wrap Tubing.
d. Prepare each cable by
stripping back the jacket
and individual wire covering
to the dimensions shown in
Figure 7.
e. Identify each wire signal
and label it (A, B, C,
D….etc.) in accordance
with Figure 7.
f. Attach a Crimp Connector
to each wire and fasten with
Crimp Tool number
M22520/1-01 and Turret
number M22520/1-02
manufactured by Astro Tool
Company or equivalent.
Note: Use the provided Large
Crimp Connector for the
Ground connection in the Control (RS-422/485) cable.
Figure 7
23-pin Connector Assembly Details