background image

Vicon Part No. 8009-8004-02-00 Section 1 Rev 500

                                                                      

XX004

Pressurized Housing Camera Dome

 

 

 

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements
or that the operation will be entirely error free or perform precisely as described in the documentation. This system
has not been designed to be used in life-critical situations and must not be used for this purpose.

Copyright © 2000 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
Teflon is a registered trademark of DuPont.

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788

TELE: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116

24-Hour Technical Support: 800-34-VICON (800-348-4266)

UK: 44/(0) 1489-566300  INFOFAX: 800-287-1207  WEB: www.vicon-cctv.com

Содержание surveyor 2000 XX004

Страница 1: ...be used in life critical situations and must not be used for this purpose Copyright 2000 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Teflon is a registered trademark of DuPont VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TELE 631 952 CCTV 2288 FAX 631 951 CCTV 2...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ... turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the us...

Страница 6: ......

Страница 7: ... Assembly 6 Installing the 23 pin Connector Assembly 7 Wiring and Assembling the 23 pin Connector 8 Final Assembly 9 Pipe Mount Method 10 Installing the Pipe Mount 10 Installing the Camera Dome 11 Pressurizing the Housing Assembly 13 Installing the 23 pin Connector Assembly 14 Wiring and Assembling the 23 pin Connector 15 Final Assembly 16 MAINTENANCE 17 Care and Cleaning of Clear Acrylic Domes 17...

Страница 8: ...roduct in any location where it may be exposed to water or moisture This does not apply to outdoor camera housings outdoor pan and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Accessories Do not place this video product on any unstable surface or table The video product may fall causing serious injury to a person and serious damage to the video product Use...

Страница 9: ...rts that could result in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 19 Damage Requiring Service Disconnect this video product from its power source and refer servici...

Страница 10: ......

Страница 11: ...Surveyor2000 s compliance at the installation site NOTE Read all instructions before beginning any installation How to Use this Manual This manual was designed to provide the best overall instructions for the installation of the Pressurized Housing version of the Surveyor2000 Camera Dome The graphics and terminology used in this manual have been carefully selected to enable a clear and distinct un...

Страница 12: ...tor is installed at the top for signal connection There is also a rectangular shaped flange surface with a four hole bolt pattern covered with gasket material that is used to attach a pipe or wall mount The inside of the Housing is factory prepared for the installation of the Surveyor2000 Camera Drive Mechanism The base of the Housing has a machined circular groove with an O ring gasket installed ...

Страница 13: ...re no obstacles behind the surface before drilling 3 Place a bead of Silicone Sealant around the Wall Mount Mounting Flange press it to the surface and line up the Flange holes with drilled holes Install the appropriate 3 8 in 9 5 mm stainless steel hardware and fasten snugly 4 Place a bead of Sealant around the Flange to Wall seam 5 If routing the cables on the outside of the Mount and through it...

Страница 14: ...c Locate the three 3 captive screws inside the Camera Drive and loosen them until the drive is free d Lift the Camera Drive out of the Enclosure e Place the Camera Drive upside down Camera facing up over the Housing resting it on the Housing edge and tilt it up about 60 12 Connect all labeled Housing cables to the mating Camera Drive connectors as shown in Figure 4 They are TB1 Power J1 Video J2 A...

Страница 15: ...d free of debris and glistening with vacuum grease If not seat the O ring in the groove remove any debris and rub additional vacuum grease on it 17 Place the Trim Ring Lower Dome Assembly on the Housing Assembly s seal surface and align the eight 8 Housing holes with the eight 8 Trim Ring Lower Dome holes Install the eight 8 screws and tighten only with a torque wrench set for 15 in lb 170 N cm of...

Страница 16: ...pressurize the Housing Assembly When the the Relief Valve opens gas will hiss from the top of the Relief Valve remove the Fill Fitting The Relief Valve is rated at 5 psi 0 5 psi 0 34 atm or bars 0 03 atm or bars Monitor the actual pressure for the next hour If in one hour the pressure has not dropped below 4 5 psi 0 31 atm or bars it is assumed that the Housing Assembly is sealed and the Relief Va...

Страница 17: ... and video RG 59 or equivalent There could be optional cables for Alarm Inputs the Relay Output jacketed twisted pair or a low pressure indicator b Prepare each cable by stripping back the jacket and individual wire covering to the dimensions shown in Figure 6 c Identify each wire on the site installed cables and label it A B C D etc in accordance with Figure 6 Repeat this on the 23 pin Connector ...

Страница 18: ...through the provided 2 in 51 mm length of Shrink Wrap Tubing and push the tubing a few feet down the cable bundle c Route all cables through the provided connector Strain Relief Fitting and push the connector near the Shrink Wrap Tubing d Prepare each cable by stripping back the jacket and individual wire covering to the dimensions shown in Figure 7 e Identify each wire signal and label it A B C D...

Страница 19: ...re 23 pin Connector Assembly Final Assembly 23 Remove the Service Cover from the front of the Wall Mount by removing the four 4 captive screws 24 Route the 23 pin Connector Assembly through the back of the Wall Mount and out the end of the Wall Mount in excess of about 2 in 51 mm If cables were previously routed through the Access Hole in previous steps ignore this step as the 23 pin Connector Ass...

Страница 20: ... Flange Caution Mount only to installed pipes with sufficient strength and as vertically level as possible 2 Install a vertically hung 1 1 2 in 38 mm diameter NPT schedule 40 pipe 3 Using the provided Teflon Tape wrap approximately 2 full turns around the threads 4 Place the Pipe Mount on the thread and turn it clockwise by hand until it fits snugly Orient the Access Cover to a convenient position...

Страница 21: ...olid surface b Remove the mask from the camera and the cardboard shipping insert Replace the mask c Locate the three 3 captive screws inside the Camera Drive and loosen them until the drive is free d Lift the Camera Drive out of the Enclosure e Place the Camera Drive upside down Camera facing up over the Housing resting it on the Housing edge and tilt it up about 60 12 Place the Camera Drive upsid...

Страница 22: ...over and shake it to remove any debris Place it back in the carton 17 Verfiy that the O ring in the groove of the Housing Assembly s seal surface is properly seated and glistening with vacuum grease If not seat the O ring in the groove remove any other extraneous debris and rub additional vacuum grease on it 18 Place the Trim Ring Lower Dome Assembly on the Housing Assembly s seal surface and alig...

Страница 23: ...pressurize the Housing Assembly When the the Relief Valve opens gas will hiss from the top of the Relief Valve remove the Fill Fitting The Relief Valve is rated at 5 psi 0 5 psi 0 34 atm or bars 0 03 atm or bars Monitor the actual pressure for the next hour If in one hour the pressure has not dropped below 4 5 psi 0 31 atm or bars it is assumed that the Housing Assembly is sealed and the Relief Va...

Страница 24: ... and video RG 59 or equivalent There could be optional cables for Alarm Inputs the Relay Output jacketed twisted pair or a low pressure indicator b Prepare each cable by stripping back the jacket and individual wire covering to the dimensions shown in Figure 12 c Identify each wire on the site installed cables and label it A B C D etc in accordance with Figure 12 Repeat this on the 23 pin Connecto...

Страница 25: ...rough the provided 2 in 51 mm length of Shrink Wrap Tubing and push the tubing a few feet down the cable bundle c Route all cables through the provided connector Strain Relief Fitting and push the connector near the Shrink Wrap Tubing d Prepare each cable by stripping back the jacket and individual wire covering to the dimensions shown in Figure 13 e Identify each wire signal and label it A B C D ...

Страница 26: ... Caution Overheating the Shrink Wrap Tubing can result in damage to the tubing and the entire 23 pin Connector Assembly Final Assembly 23 Remove the Access Cover from the front of the Pipe Mount by removing the four 4 screws 24 Route the 23 pin Connector Assembly through the pipe and the Pipe Mount to the end of the Pipe Mount in excess of about 2 in 51 mm 25 Inspect the top of the Housing Assembl...

Страница 27: ...a solution of mild soap or isopropyl alcohol and water using a lint free soft paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft cleaning cloth Caution Excessive rubbing of the Lower Dome surface can cause permanent scratches 5 Clean all surfaces with any soft cleaning cloth and a mild glass cleanser su...

Страница 28: ...18 Maintenance XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome NOTES ...

Страница 29: ... from countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem a...

Страница 30: ...20 Shipping Instructions XX004 Rev 500 Surveyor2000 Pressurized Housing Camera Dome NOTES ...

Страница 31: ... The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring to the characteristics and maximum distances listed below The maximum distance for best picture refers to the distance between the receiver and the transmitter The charact...

Страница 32: ... pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the CPU Keypad and the Camera Dome Assembly The characteristics of the cables in Table 3 should be used as a guideline when cables other than Belden are used Materials and construct...

Страница 33: ...tor included for access to all Surveyor2000 signals including heater blower power communications and video Heater Power 70 W Will be capable of a cold start de icing of the lower dome Fan Cooling Rate 16 cfm 126 ccm Fuse 5x20 mm 4 A 250 VAC slo blo Surveyor2000 has separate internal fuses Safety Standard UL 2204 and CSA C22 2 No 1 Radio Frequency Emission Rating FCC Class A European Community CE S...

Страница 34: ...L Pressurization Schraeder type valve used to fill and drain housing with dry Nitrogen gas Relief valve automatically relieves pressure at greater than 7 psi 0 48 atm Operating Pressure 1 5 psi 0 07 0 34 atm or bars maximum Relief Pressure 7 psi 0 48 atm or bars maximum Low Pressure switch A normally open NO switch output available on connector for use as external alarm Video Pan View 360 Video Ti...

Страница 35: ...me Technical Information 25 ENVIRONMENTAL Ambient Temperature and Humidity Range 30 F 34 C to 110 F 43 C maximum Up to 100 relative humidity condensing Maintained Temperature and Humidity Range 14 F 10 C to 140 F 60 C maximum Up to 90 relative non condensing ...

Страница 36: ...Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712 8781 Vicon China Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...