Operation, Remote Operation
Measurement Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 8
Subject to Export Control. See Cover Page for details.
February 2020
5.3.4
PULSE
Command Syntax:
{:ATC |:ATC5000NG}{:MEA |:MEASURE}{:SET |:SETTINGS}{:PUL |:PULSE}SP<value>CR
Description:
This command sets the measurement routine to sample the selected pulse. Pulse selected to
sample interrogation is ignored when the scenario type selected is XPDR.
Value
0|F1
1|C1
2|A1
3|C2
4|A2
5|C4
6|A4
7|B1
8|D1
9|B2
10|D2
11|B4
12|D4
13|F2
14|P1MSR
15|P2MSR
16|P3MSR
17|P4MSR
18|S1MCI
19|P1MCI
20|P2MCI
21|P3MCI
22|P4MCI
23|P1MSI
24|P2MSI
25|P6MSIR
26|P6MSIF
27|P6MSI
28|P6SPR
29|MCSPI
30|DFDATA
31|DMEXP1
32|DMEXP2
33|DMEYP1
34|DMEYP2
35|MCXBIT
Pulse
F1 ATCRBS Reply
C1 ATCRBS Reply
A1 ATCRBS Reply
C2 ATCRBS Reply
A2 ATCRBS Reply
C4 ATCRBS Reply
A4 ATCRBS Reply
B1 ATCRBS Reply
D1 ATCRBS Reply
B2 ATCRBS Reply
D2 ATCRBS Reply
B4 ATCRBS Reply
D4 ATCRBS Reply
F2 ATCRBS Reply
P1 Mode S Reply
P2 Mode S Reply
P3 Mode S Reply
P4 Mode S Reply
S1 ATCRBS Interrogation
P1 ATCRBS Interrogation
P2 ATCRBS Interrogation
P3 ATCRBS Interrogation
P4 ATCRBS Interrogation
P1 Mode S Interrogation
P2 Mode S Interrogation
P6 Start Interrogation
P6 End Interrogation
P6 Mode S Interrogation
P6 SPR
SPI ATCRBS Reply
DF Frame Data
DME X P1
DME X P2
DME Y P1
DME Y P2
X ATCRBS Reply
Example:
:ATC:MEA:SET:PUL 18\r
Default:
Scenario Type
XPDR
0|F1
MULTI (Multi-Receiver)
19|P1MCI
Query:
:ATC:MEA:SET:PUL?\r
Return:
18