Operation, Remote Operation
RTCA/DO-260 Test Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 21
5.6.1.9
MODE S DATA
5.6.1.10
MODE S PULSE PARAMETERS
5.6.1.10.1
PREAMBLE DELTA PULSE POSITION
5.6.1.10.2
PREAMBLE DELTA PULSEWIDTH
5.6.1.10.3
PREAMBLE PULSE ENABLE
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL } {:GENS}{:GENA |:GENB |:GENC |:GEND
|:GENE |:GENF } {:MODES} {:DATA}SP<mode s hex data>CR
{:ATC |:ATC5000NG}{:DO260}{:TYPE} {:OVERLAPPINGPULSE |:OVERLAP
|:ALTEREDPREAMBLE |:ALT |:BITFAILURES |:BITF |:PREAMBLEVAL |:PREA }
{:GENS}{:GENA } {:MODES} {:DATA}SP<mode s hex data>CR
Description:
This command defines the Mode S message to transmit through the selected generator. For long
Mode S, the <mode s hex data> contains 28 hexadecimal figures. For short Mode S, the <mode
s hex data> contains 14 hexadecimal figures. The last six hexadecimal figures are used to define
the Mode S Address. By default, the Mode S data is 00000000000001.
Example:
:ATC:DO260:TYPE:NORMAL:GENS:GENA:MODES:DATA 8800000148000000000000000001\r
Example:
:ATC:DO260:TYPE:ALT:GENS:GENA:MODES:DATA F100088\r
Default:
00000000000001
Query:
:ATC:DO260:TYPE:ALT:GENS:GENA:MODES:DATA?\r
Return:
0000000FEFA0C0
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL}{:PULSE}{:MODES:CH:}{ 1 | 2 | 3 | 4 | 5 |
6}{:P2 |:P3 |:P4 }{:DPOS}SP<numeric>CR
Description:
This command sets the delta position of the selected Mode S pulse on the selected generator.
Numeric:
-1000 to 1000 ns in 25 ns steps (decimal ASCII)
Example:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:3:P3:DPOS 25\r
Default:
0
Query:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:3:P3:DPOS?\r
Return:
25
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL}{:PULSE}{:MODES:CH:}{ 1 | 2 | 3 | 4 | 5 |
6}{:P1 |:P2 |:P3 |:P4 }{:DWIDTH}SP<numeric>CR
Description:
This command sets the delta width of the selected Mode S pulse on the selected generator.
Numeric:
-400 to 400 ns in 25 ns steps (decimal ASCII)
Example:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:2:P3:DWIDTH 200\r
Default:
0
Query:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:2:P3:DWIDTH?\r
Return:
200
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL}{:PULSE}{:MODES:CH:}{ 1 | 2 | 3 | 4 | 5 |
6}{:P1 |:P2 |:P3 |:P4 }{:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables (not visible) the selected Mode S pulse.
Example:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:4:P4:ENABLE OFF\r
Default:
On
Query:
:ATC:DO260:TYPE:NORMAL:PULSE:MODES:CH:4:P4:ENABLE?\r
Return
OFF