Appendix D - ATC-5000NG Compatibility Command Set
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
Appendix -
D
February 2020
Subject to Export Control. See Cover Page for details.
Page 15
WN
Partial
Command is accepted. No action is taken.
Use :ATC:MEAS:PUL:POS? for spacing measurement.
:ATC:MEAS:PUL:POS?
Set Narrow Tolerance Window
WW
Partial
Command is accepted. No action is taken.
Use :ATC:MEAS:PUL:POS? for spacing measurement.
:ATC:MEAS:PUL:POS?
Set Wide Tolerance Window
X1
No
Set XPDR Mode 1
X2
No
Set XPDR Mode 2
XA
Yes
:ATC:XPDR:DBL:2:MOD 0 or
:ATC:XPDR:ITABLE:1:MOD 0 or
:ATC:XPDR:MOD 0
Set XPDR Mode A
XB
No
Set XPDR Mode B
XC
Yes
:ATC:XPDR:DBL:2:MOD 1 or
:ATC:XPDR:ITABLE:1:MOD 1 or
:ATC:XPDR:MOD 1
Set XPDR Mode C
XD
No
Set XPDR Mode D
XT
No
Set XPDR Mode T
XA1
Yes
See double mode
Set XPDR Mode AC1
XA2
Yes
See double mode
Set XPDR Mode AC2
XP
Yes
:ATC:XPDR:PUL:P1W
:ATC:XPDR:DBL:1:PUL:P1W
:ATC:XPDR:ITABLE:1:PUL:P1W
Set XPDR Pulse Width (0.10 to 1.95 μs in 0.05 μs steps)
XP0
Yes
:ATC:XPDR:PUL:P1W
:ATC:XPDR:DBL:1:PUL:P1W
:ATC:XPDR:ITABLE:1:PUL:P1W
Set XPDR Pulse Width to CAL
XP1
Yes
:ATC:XPDR:PUL:P1W
:ATC:XPDR:DBL:1:PUL:P1W
:ATC:XPDR:ITABLE:1:PUL:P1W
Set XPDR Pulse Width (0.10 to 1.95 μs)
XV
Yes
On the 1400A pulses will merge and create a single pulse when P2 set
to -1.8us.
On the 5000 the pulses do not merge completely.
:ATC:XPDR:PUL:P12S
:ATC:XPDR:DBL:1:PUL:P12S
:ATC:XPDR:ITABLE:1:PUL:P12S
Set P2/P3 Deviation (0. to 1.95 μs in 0.05 μs steps)
XV20
Yes
:ATC:XPDR:PUL:P12S
:ATC:XPDR:DBL:1:PUL:P12S
:ATC:XPDR:ITABLE:1:PUL:P12S
Set P2 Pulse Spacing to CAL
ATC-1400A
Supported
Comments
ATC5000NG Equivalent
(or Similar)
Command description