Operation, Remote Operation
Scenario Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 34
Subject to Export Control. See Cover Page for details.
February 2020
5.7.1.4
1030 MESSAGES BLOCK MESSAGE TYPE
5.7.1.5
1030 MESSAGES BLOCK MESSAGE DATA
5.7.2
INTRUDERS DEFINITION PARAMETERS
5.7.2.1
ALTITUDE MODE
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:I1030:}<message number>{:TYPE }SP<numeric>CR
Description:
This command sets the type of the 1030 message selected.
Numeric:
Value
1
2
3
4
5
6
7
Type
Mode S Interrogation
Mode A
Mode C
Mode A All Call
Mode C All Call
Mode A/Mode S All
Call
Mode C/Mode S All
Call
Example:
:ATC:SCE:I1030:2:TYPE 2\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:I1030:}<message number>{:MESS |:MESSAGE
}SP<numeric>CR
Description:
This command sets the data message for the selected 1030 message.
Numeric:
Short interrogation: 0 to FFFFFFFFFFFFFF (14 hexadecimal ASCII)
Long interrogation: 0 to FFFFFFFFFFFFFFFFFFFFFFFFFFFF ( 28 hexadecimal ASCII)
The last six characters are the Mode S Address.
Example:
:ATC:SCE:I1030:1:MESS 000404000F6705\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:AMODE}SP{GILHAM | BINARY}CR
Description:
This command sets the altitude data mode to either Gilham or Binary.
Altitude Binary Mode: -1000 to 50175 feet in 25 feet resolution
Altitude Gilham Mode: -1000 to 126700 feet in 100 feet resolution
Example:
:ATC:SCE:STAT:1:AMODE GILHAM\r
Default:
Binary
Содержание 138156
Страница 3: ......