Operation, Remote Operation
RTCA/DO-260 Test Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 22
Subject to Export Control. See Cover Page for details.
February 2020
5.6.1.11
POWER LEVEL
5.6.1.12
RANDOM MODE S DATA ON/OFF
5.6.1.13
RANDOM STARTING POSITION ON/OFF
5.6.1.14
WALK ON/OFF
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL } {:GENS}{:GENA |:GENB |:GENC |:GEND
|:GENE |:GENF} {:POWER |:POW}SP<numeric>CR
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:OVERLAPPINGPULSE |:OVERLAP
|:ALTEREDPREAMBLE |:ALT |:BITFAILURES |:BITF |:PREAMBLEVAL |:PREA }
{:GENS}{:GENA |:GENC } {:POWER |:POW}SP<numeric>CR
Description:
This command sets the selected generator output power level.
Numeric:
-20 to -90 dBm (decimal ASCII)
Example:
:ATC:DO260:TYPE:NORMAL:GENS:GENC:POW -30\r
Example:
:ATC5000NG:DO260:TYPE:ALTEREDPREAMBLE:GENS:GENA:POWER -30\r
Default:
-20 dBm
Query:
:ATC:DO260:TYPE:NORMAL:GENS:GENC:POW?\r
Return:
-30
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL } {:GENS}{:GENA |:GENB |:GENC |:GEND
|:GENE |:GENF } {:MODES} {:RANDOM}SP{ON | OFF}CR
Description:
This command enables or disables the random generation of Mode S Pulse to transmit using the
selected generator.
Example:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:MODES:RANDOM ON\r
Default:
Off
Query:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:MODES:RANDOM?\r
Return:
ON
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL } {:GENS}{:GENA |:GENB |:GENC |:GEND
|:GENE |:GENF } {:RSPOS}SP{ON | OFF}CR
Description:
This command enables or disables the random starting position generation of the pulse to
transmit using the selected generator. For the generator trigger source, the random starting
position is disabled. If the random starting position is disabled with trigger mode set to random,
then the starting position is the trigger source position plus the delay Value for that specific
generator.
Example:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:RSPOS OFF\r
Default:
On
Query:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:RSPOS?\r
Return:
OFF
Command Syntax:
{:ATC |:ATC5000NG}{:DO260}{:TYPE}{:NORMAL } {:GENS}{:GENA |:GENB |:GENC |:GEND
|:GENE |:GENF }{:WALK}SP{ON | OFF}CR
Description:
This command enables or disables the walk status of the transmission using the selected
generator. For the generator trigger source, the walk status is disabled. If walk is disabled, the
transmission begins the delay Value from the trigger source. If walk is enabled, the transmission
initially begins at the delay Value and moves 50 ns every transmission until the end.
Example:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:WALK OFF\r
Default:
On
Query:
:ATC5000NG:DO260:TYPE:NORMAL:GENS:GENA:WALK?\r
Return:
OFF
Содержание 138156
Страница 3: ......