Operation, Remote Operation
Transponder Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 119
5.9.17.3.5
TABLE ENTRY ANTENNA POWER DEVIATION
5.9.17.3.6
TABLE ENTRY ANTENNA TIME DEVIATION
5.9.17.3.7
TABLE ENTRY ENABLE
Command Syntax:
{:ATC |:ATC5000NG}{:XPDR}{:ITABLE:}<table entry>{:ANT |:ANTENNA}{:POW
|:POWER}SP<numeric>CR
Description:
This command sets the antenna power deviation between the top and bottom antenna of the
selected table entry.
Table Entry:
1 to 1000 (decimal ASCII)
Numeric:
-20 to 20 dB (decimal ASCII)
Default:
0
Example:
:ATC:XPDR:ITABLE:2:ANT:POW -19\r
Query:
:ATC:XPDR:ITABLE:2:ANT:POW?\r
Return:
-19.0
Command Syntax:
{:ATC |:ATC5000NG}{:XPDR}{:ITABLE:}<table entry>{:ANT |:ANTENNA}{:TIM
|:TIME}SP<numeric>CR
Description:
This command sets the antenna time deviation between the top and bottom antenna of the
selected table entry.
Table Entry:
1 to 1000 (decimal ASCII)
Numeric:
-0.975 to 0.975 µs (decimal ASCII)
Default:
0
Example:
:ATC:XPDR:ITABLE:1:ANT:TIM 0.5\r
Query:
:ATC:XPDR:ITABLE:1:ANT:TIM?\r
Return:
0.5
Command Syntax:
{:ATC |:ATC5000NG}{:XPDR}{:ITABLE:}<table entry>{:ENABLE}SP{ON | OFF}CR
Description:
This command turns on or off the interrogation of the selected table entry.
Table Entry:
1-1000 (Decimal ASCII)
Default:
ON
Example:
:ATC:XPDR:ITABLE:1:ENABLE OFF\r
Query:
:ATC:XPDR:ITABLE:1:ENABLE?\r
Return:
OFF