Operation, Remote Operation
Settings Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 99
5.8.2
SCOPE PORT
5.8.3
TX GENERATOR PARAMETERS
Command Syntax:
{:ATC |:ATC5000NG}{:SET |:SETTINGS}{:SCO |:SCOPE}{:CH1 | :CH2}SP<numeric>CR
Description:
This command sets the scope multiplexer for Scope 1 or Scope 2 to the signal represented by
the numeric value.
Numeric:
0 to 31 (decimal ASCII)
Value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Receiver
1090 Log Video Top
1030 Log Video Top
1090 Log Video Bottom
1030 Log Video Bottom
DPSK 1030 Top (Delay) Not Used
DPSK 1030 Bottom (Delay) Not Used
Transmitter 1 (Gen A) Pulse Modulation
Transmitter 2 (Gen B) Pulse Modulation
Transmitter 3 (Gen C) Pulse Modulation
Transmitter 4 (Gen D) Pulse Modulation
Transmitter 5 (Gen E) Pulse Modulation
Transmitter 6 (Gen F) Pulse Modulation
Transmitter 2 (Gen B) DPSK Modulation
Transmitter 4 (Gen D) DPSK Modulation
Transmitter 6 (Gen F) DPSK Modulation
I 1030 Top Receiver
I 1030 Bottom Receiver
Q 1030 Top Receiver
Q 1030 Bottom Receiver
I 1090 Top Receiver
I 1090 Bottom Receiver
Q 1090 Top Receiver
Q 1090 Bottom Receiver
Suppression In
Sync
Sync (Transmitter FPGA Test Point)
Log Video 1030 Digital AGC Video
Log Video 1090 Digital AGC Video
DPSK Demodulation
+3.3 V Monitor
+1.8 V Monitor
+1.2 V Monitor
Default:
Last state before power down.
Example:
:ATC:SET:SCO:CH1 24\r
Query:
:ATC:SET:SCO:CH1?\r
Return:
24
NOTE
The Generator commands are for use in the RTCA/DO-260 Test mode and Factory calibration
ONLY. To set power and frequency use commands listed under the specific test sections.
Содержание 138156
Страница 3: ......