WDV Series Gas Fireplace
CLEARANCES
MANTEL CLEARANCES
NOTE:
The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
6”
5”
3”
4
¹⁄₂
”
45°
1”
3
¹⁄₂
”
FP2423
mantel leg
1
¹⁄₂
”
2
¹⁄₂
”
FP2423
Side of
Fireplace
Opening
Figure 5 -
Mantel clearances
Top View
CLEARANCES TO COMBUSTIBLES
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
The appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
W
ARNING
54” Minimum
Ceiling
12” Max.
Depth
2
1
/
2
” Max
Depth
6” Min.
From Opening
12” Min.
From Opening
6” Min.
FP2421
mantel clearances
5
³⁄₄
”
Min. to Combustibles
Figure 4 -
Ceiling and Sidewall Clearances