20306744
5
WDV Series Gas Fireplace
PRODUCT FEATURES
Figure 1 -
WDV Fireplace Features
PRODUCT SPECIFICATIONS
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).
GAS PRESSURES
GAS SPECIFICATIONS & ORIFICE SIZE
Orifice
Max.Input Min. Input Size
Model
Fuel
BTU/h
BTU/h
Qty. (2)
WDV500NTSC Nat.
34,000
23,000
#43
WDV500PTSC
LP
33,000
25,500 1.28 mm
WDV600NTSC Nat.
45,000
28,000
#36
WDV600PTSC
LP
40,000
32,000
1.5 mm
BEFORE YOU START
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
•
Fireplace (Firebox and Burner System)
•
Reflective Glass
•
Stone Set
ITEMS REQUIRED FOR INSTALLATION
•
Phillips Screwdriver
•
Framing Materials
•
Hammer
•
Wall Finishing Materials
•
Saw and/or saber saw
•
Level
•
Measuring Tape
•
Pliers
•
Electric Drill and Bits
•
Square
•
Pipe Wrench
•
Tee Joint
•
Caulking Material (noncombustible)
•
Fireplace Surround Material (noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to sulfur compounds)
•
Noncombustible finishing material or dura-rock*
* Only used if desired to cover painted face other than using tiles or
marble. If tiles or marble are used around the face, the noncombustible
material is not needed.
FP2429
DVW prod features
FP2429
Gas Valve
Command
Center
Control Box &
A/C Module
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c
Manifold Pressure
3.5” w.c.
10.0” w.c.