TROUBLESHOOTING
Figure 56
SIGNATURE COMMAND SYSTEM OPERATION
Symptom
Causes
Action
Battery icon on LCD on transmitter Low Battery
Replace batteries. Change batter-
ies every 6 months.
LCD display is blank
Low Battery
Check battery installation or replace
batteries.
LCD display shows “funny” display Low Battery
Reset the transmitter (see "Reset-
ting the Transmitter" setting)
Appliance does not come on
The transmitter did not match with the
receiver.
Transmitter measures temperature
exceeding 99°F and shows "HI" on LCD.
Distance between the transmitter and
receiver is more than 30 feet.
Make sure the transmitter has
learned to the receiver.
Move transmitter to a cooler place
and wait until temperature drops
below 99°F.
Make sure the opening distance is
less than 30 feet.
Blower is not on after the fireplace
is turned on
Blower setting is off.
Blower delay setting is set too high.
Press FAN key to select fan speed
desired.
Press and hold FAN key to set
desired ON/OFF delays. This is
done in minutes.