VWDV70 Series Gas Fireplace
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
FEATURES
Command Center
•
Easy Access Function Operation and System Con
fi
g-
uration
•
Operation
Con
fi
rmation/Fault Diagnostic Indications
(LED/Buzzer)
•
ON/OFF/HI/Med/Low
Operation
•
Optional Wall Mounting
Control Board
•
Electronic
Ignition
•
Pilot Lockout safety feature
•
Electric Power Regeneration from Thermopile to save
battery
•
6-hour Automatic Shut Down Option
•
Convenient NG/LP Gas Type Conversion
•
Standing Pilot/Intermittent pilot Conversion
•
Previous settings Restoration Ability (Memory Off)
•
Uninterrupted Operation During Power Outage (Auto-
matic Battery Backup)
•
ON/OFF RF Remote Receiver
•
Optional Transmitter Learn Capability
AC Module (Requires TSFSC Remote)
•
Easy Snap-on Design
•
Embedded Compact 120 VAC Adapter with Auto Bat-
tery Back up Feature
•
Remote Controlled 3-step Blower, Lighting, and On/
Off Auxiliary AC Outputs
Transmitter
TSFSC
Three Flame Height Settings
X
Low battery Indication for Transmitter
X
Child Proof Lock-out
X
LCD Backlight
X
Security Codes 16
X
Countdown 6 hr Timer
X
Standard Thermostatic Control Mode
X
Smart Mode Thermostat
(Auto Flame & Blower Modulation)
X
Three Brightness Settings for Lights
X
Three Speed Control for Blower
X
On/Off Auxiliary
X
Programmable Timer to turn blower on and off
X
BATTERY INSTALLATION
The Command Center uses four (4) "AA" batteries as
back up for power outages. The system can operate for
approximately six (6) months on battery power.
To Install Batteries (not included):
1. Press down the battery door tabs and pull out to remove
battery door.
Figure 59 -
Signature Command System Components
RF Receiver
ON/OFF
NG/LP
Conversion
To Thermopile
To Sensor
To Sparker
To Command Center
To Stepper Motor
To Valve
Battery Door
Master
Switch
ON
LED
OFF
Control Board
Command Center
AC Module
FP1917
2. Install the batteries as indicated on Command Center.
3. Close battery door by snapping in place.
4. When the four (4) batteries are installed the system will
operate without power.
5. The batteries should be replaced when the LED indi-
cates low battery or at least once a year.
SYSTEM CONFIGURATION/SETUP
All System con
fi
guration/setup is done on the Command
Center.
NOTE:
When using On/Off wall switch, the switch must be
in the ON position to perform all con
fi
guration set ups at
the command center.
COLD CLIMATE OPTION
Choose the Mode That Best Suits Your Needs
The Signature Command System is designed to operate
in either Standing Pilot or Intermittent Pilot mode.
•
The Standing Pilot Mode is best for colder climates
when the pilot must remain on continuously to prevent
condensation and ensure reliable operation.
•
The Intermittent Pilot Mode is ideal for maximum ef
fi
-
ciency, igniting the pilot only when needed to start your
fi
replace, lowering fuel consumption and reducing your
carbon footprint.