20306745
5
VWDV70 Series Gas Fireplace
PRODUCT FEATURES
Figure 1 -
VWDV70 Fireplace Features
PRODUCT SPECIFICATIONS
•
This appliance has been certi
fi
ed for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a
venting system.
•
The appliance is not approved for closet or recessed
installations.
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certi
fi
ed
without derating for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).
GAS PRESSURES
BEFORE YOU START
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
•
Fireplace (Firebox and Burner System)
•
Re
fl
ective Decorative Glass
•
Conversion Kit
•
Stone
Set
•
Wall Switch Kit
ITEMS REQUIRED FOR INSTALLATION
•
Phillips Screwdriver
•
Framing Materials
•
Hammer
•
Wall Finishing Materials
•
Saw and/or saber saw
•
Level
•
Measuring Tape
•
Pliers
•
Electric Drill and Bits
•
Square
•
Pipe Wrench
•
Tee Joint
•
Caulking Material (noncombustible)
•
Fireplace Surround Material (noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to sulfur compounds)
•
Noncombustible
fi
nishing material or dura-rock*
* Only used if desired to cover painted face other than using tiles or
marble. If tiles or marble are used around the face, the noncombustible
material is not needed.
FIREBOX FRAMING
Firebox framing can be built before or after the appliance
is set in place. Refer to
Figure 2
for
fi
replace and framing
dimensions. The framing headers may rest on the top of the
fi
rebox standoffs. Do not bring headers below top of stand-
offs.
NOTE:
When planning your framing and installation,
keep in mind that both the gas line and electricity should
come in on the right side of the
fi
rebox (as you are facing
the front of the
fi
replace).
The
fi
rebox may be installed directly on a combustible
fl
oor
or raised on a platform of an appropriate height. When
the
fi
rebox is installed directly on carpeting, tile, or other
combustible material, other than wood
fl
ooring, the
fi
rebox
shall be installed on a metal or wood panel extending the
full width and depth of the enclosure.
GAS SPECIFICATIONS & ORIFICE SIZE
Max. Min.
Input
Input
Orifi ce Sizes
Model
Fuel Btu/hr Btu/hr
Left Middle Right
VWDV70
Nat.
51,000
32,500
#44 #43 #45
VWDV70
LP 43,000 32,000 1.25 mm 1.20 mm #56
FP2938
Side View
Control Board
A/C Module
Gas Control
Valve
Natural
Propane (LP)
Inlet Minimum
4.5" w.c.
11.0" w.c.
Inlet Maximum
10.5" w.c.
13.0" w.c.
Manifold Pressure
3.5" w.c.