3200A
|
Error Messages
63
5
VALVE
NOT
PRESENT
ERROR
302
With
system
in
operation,
the
communication
between
valve
and
control
unit
is
disrupted.
Error
Code
Display:
VALVE
NOT
PRESENT
ERROR
302
Error
Code
Status
Menu:
VALVE
NOT
PRESENT
ERROR
302
Corrective
Action:
Switch
OFF
control
unit,
and
verify
both
of
the
connections
(sensor
and
actuator
cable).
Defective
cables
must
be
exchanged.
Otherwise,
the
valve
must
be
returned
to
the
manufacturer.
6
VALVE
DEFECT
ERROR
501
The
valve
during
operation
fails,
e.g.
due
to
a
damaged
piezoelectric
element.
Error
Code
Display:
VALVE
DEFECT
ERROR
501
Error
Code
Status
Menu:
VALVE
DEFECT
ERROR
501
Corrective
Action:
The
valve
must
be
returned
to
the
manufacturer.
7
MDV
TEMP.
HIGH
PLEASE
WAIT
In
order
to
protect
the
piezoelectric
element
from
excessive
heat,
the
temperature
is
inter
‐
nally
monitored
by
a
corresponding
circuit,
automatically
switching
OFF
the
system
in
case
of
need.
Limits:
NL
≤
80
%
=
140
°C
NL
>
80
%
=
120
°C
Error
Code
Display:
MDV
TEMP.
HIGH
PLEASE
WAIT
Error
Code
Status
Menu:
TEMP
ERROR
502
Corrective
Action:
Switch
OFF
the
system.
A
certain
cooling
phase
is
required
anyway.
Maybe
the
values
for
Needle
Lift
and/or
Frequency
parameters
have
to
be
lowered,
in
order
to
prevent
reoccur
‐
rence
of
the
problem.
Another
source
of
the
problem
may
be
defective
sensor
and
actuator
cable
connections
(loosened
plugs,
damaged
cables).
Before
inspection,
do
not
forget
to
switch
OFF
the
control
unit.
8
DATA
ERROR
PRESS
ENTER
During
the
check
of
RAM
data,
a
problem
arises.
The
message
has
to
be
acknowledged
by
[enter]
key.
The
system
reformats
the
EEPROM,
replacing
current
values
by
the
factory
set
‐
tings.
Error
Code
Display:
DATA
ERROR
PRESS
ENTER
Error
Code
Status
Menu:
BAD
DATA
Corrective
Action:
Press
[enter]
key.
This
way
all
of
the
current
values
are
erased
and
replaced
by
the
factory
settings.
The
desired
dispensing
parameters
have
to
be
reentered.
Due
to
this
reason,
it
is
recommended
that
users
keep
sepa
‐
rate
notes
concerning
the
current
configuration!
This
allows
for
quick
reaction
in
case
of
need.
Содержание MDS 3000 Series
Страница 1: ......
Страница 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Страница 71: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 71 13 ATTACHMENT 13 1 EC Declaration of Conformity...
Страница 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Страница 73: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 73 13 3 Dimensional Drawing MDV 3200A with MDX 3080 CC...
Страница 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...