VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Communication Interfaces
42
9.
LCD?
Description:
This
command
is
useful
to
inspect
externally
the
current
content
of
the
screen.
Example:
Input:
LCD?
Result:
When
sending
this
command
immediately
after
switching
ON,
the
content
of
the
screen
will
be
“READY
Maint.“
Return:
(
in
this
case
)
“Ready
Maint.“
10.
SYSTEM:KLOCK:OFF
Description:
Access
to
keypad
is
permitted,
the
locking
function
disabled.
Example:
Input:
SYSTEM:KLOCK:OFF
Result:
The
keypad
of
the
control
unit
can
be
used
from
now
on.
Return:
OK
11.
SYSTEM:KLOCK:ON
Description:
This
instruction
locks
the
keypad
of
the
control
unit.
This
way
un
‐
authorized
modification
of
parameters
can
be
prevented.
Example:
Input:
SYSTEM:KLOCK:ON
Result:
The
keypad
is
locked.
Return:
OK
12.
TEMP:?
Description:
The
user
is
informed
about
the
current
(real)
temperature
of
the
nozzle
heater;
the
measuring
unit
is
°C.
Example:
Input:
TEMP:?
Result:
70
…
the
current
temperature
value
amounts
to
70
°C.
Return:
70
13.
TEMP:<Setpoint
in
°C>
Description:
This
command
is
used
to
select
a
new
target
value
for
the
heater;
the
measuring
unit
is
°C.
Example:
Input:
TEMP:60
Result:
From
now
on,
the
temperature
control
sets
the
heating
temperature
to
60
°C.
Return:
OK
14.
MAINT:STATUS
Содержание MDS 3000 Series
Страница 1: ......
Страница 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Страница 71: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 71 13 ATTACHMENT 13 1 EC Declaration of Conformity...
Страница 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Страница 73: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 73 13 3 Dimensional Drawing MDV 3200A with MDX 3080 CC...
Страница 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...