VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Communication Interfaces
44
Ramp
parameters
(i.e.
values
relating
to
time)
have
to
be
specified
in
1/10
ms,
except
for
“Falling“
which
has
to
be
entered
in
1/100
ms.
Values
lower
than
“1”
are
not
admissible.
Therefore
the
minimum
Falling
value
amounts
to
0,01
ms
(10
%
NL),
the
minimum
Rising
value
0,1
ms
(1
%
NL)
.
Specified
values
must
be
integer
and
positive.
If
the
External
Mode
is
de
‐
sired,
instead
of
a
numerical
value,
enter
“EXTERNAL”
for
“Open
Time”.
The
start
of
a
dispensing
cycle
with
the
selected
parameter
configuration
is
initiated
by
the
command
“VALVE:OPEN“
(instruction
no.
21,
see
below).
Example:
Input:
TRIGGER:SET:10,10,15,90,20,8
Result:
This
way,
the
following
values
are
assigned
to
the
parameters:
Rising:
10
≙
1,0
ms
(ms
=
Millisecond)
Open
Time:
10
≙
1,0
ms
Falling:
15
≙
0,15
ms
Needle
Lift:
90
%
Number
of
Pulses:
20
Delay:
8
≙
0,8
ms
Return:
OK
18.
TRIGGER:SET:<Rising>,<Open
Time>,<Falling>,<Needle
Lift>,<Number
of
Pulses>,<Delay>,1
Description:
With
this
command
cycle
parameters
can
be
modified
and
saved
in
the
EEPROM
of
the
control
unit
(Reaction
time:
1200
ms)
.
The
entered
set
thus
remains
available
for
future
use.
A
trigger
command
however
is
not
launched,
but
can
be
initiated
by
means
of
command
no.21
“VALVE:OPEN“,
so
that
a
dispensing
cycle
with
this
parameter
set
immediately
starts.
Ramp
parameters
(i.e.
values
relating
to
time)
have
to
be
specified
in
1/10
ms,
except
for
“Falling“
which
has
to
be
entered
in
1/100
ms.
Values
lower
than
“1”
are
not
admissible.
Therefore
the
minimum
Falling
value
amounts
to
0,01
ms
(10
%
NL)
,
the
minimum
Rising
value
0,1
ms
(1
%
NL)
.
Specified
values
must
be
integer
and
positive.
If
the
External
Mode
is
de
‐
sired,
instead
of
a
numerical
value,
enter
“EXTERNAL”
for
“Open
Time”.
Example:
Input:
TRIGGER:SET:10,10,15,90,20,8,1
Result:
The
following
values
are
assigned
to
the
parameters:
Rising:
10
≙
1,0
ms
(ms
=
Milliseconds)
Open
Time:
10
≙
1,0
ms
Falling:
15
≙
0,15
ms
Needle
Lift:
90
%
Number
of
Pulses:
20
Delay:
8
≙
0,8
ms
Return:
OK
Содержание MDS 3000 Series
Страница 1: ......
Страница 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Страница 71: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 71 13 ATTACHMENT 13 1 EC Declaration of Conformity...
Страница 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Страница 73: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 73 13 3 Dimensional Drawing MDV 3200A with MDX 3080 CC...
Страница 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...