64
9
INTERNAL
ERROR
701
A
hardware
failure
of
the
valve
control
is
probable
(e.g.
short
circuit
in
the
connection
of
the
piezoelectric
element).
This
problem
is
possible
during
startup
of
the
control
unit
and
also
with
system
in
operation.
Error
Code
Display:
INTERNAL
ERROR
701
Error
Code
Status
Menu:
DAC
LOAD
ERROR
Corrective
Action:
The
control
unit
must
be
switched
OFF,
at
once.
Inspect
the
actuator
cable
connection.
Worn,
kinked
or
charred
cables
must
be
exchanged.
The
valve
must
be
returned
to
the
manufacturer.
The
MDC
has
to
be
checked.
10
EEPROM
Error
Press
Enter
A
corrupted
memory
area
becomes
obvious
when
reading
the
EEPROM.
Error
Code
Display:
EEPROM
Error
Press
Enter
Error
Code
Status
Menu:
EEPROM
NOT
FORMATED
Corrective
Action:
Press
[enter]
key.
This
way
all
of
the
current
values
are
erased
and
replaced
by
the
factory
settings.
The
desired
dispensing
parameters
have
to
be
reentered.
11
EEPROM
Error
Press
Enter
The
problem
can
occur
when
writing
data
to
the
EEPROM.
Error
Code
Display:
EEPROM
Error
Press
Enter
Error
Code
Status
Menu:
EEPROM
WRITE
ERROR
Corrective
Action:
Acknowledge
the
message
by
pressing
[enter]
.
If
the
problem
arises
when
modifying
program
parameters,
the
new
values
are
not
saved
in
the
EEPROM.
After
restart
of
the
control
unit,
the
former
values
therefore
still
remain
in
force.
12
EEPROM
Error
Press
Enter
The
storing
procedure
for
a
set
‐
up,
initiated
by
the
[save]
key,
fails.
Error
Code
Display:
EEPROM
Error
Press
Enter
Error
Code
Status
Menu:
EEPROM
SAVE
ERROR
901
Corrective
Action:
Acknowledge
the
message
by
pressing
[enter]
.
If
the
problem
arises
when
modifying
program
parameters,
the
new
values
are
not
saved
in
the
EEPROM.
After
restart
of
the
control
unit,
the
former
values
therefore
still
remain
in
force.
13
EEPROM
Error
Press
Enter
This
problem
may
arise
during
the
retrieval
of
a
setup,
by
[recall]
key.
Error
Code
Display:
EEPROM
Error
Press
Enter
Error
Code
Status
Menu:
EEPROM
LOAD
ERROR
902
Corrective
Action:
The
message
has
to
be
acknowledged
by
[enter]
.
Repeat
the
procedure.
If
the
problem
persists,
new
data
have
to
be
entered
to
the
corresponding
memory
position.
Содержание MDS 3000 Series
Страница 1: ......
Страница 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Страница 71: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 71 13 ATTACHMENT 13 1 EC Declaration of Conformity...
Страница 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Страница 73: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 73 13 3 Dimensional Drawing MDV 3200A with MDX 3080 CC...
Страница 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...