VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Operation
34
6.3
Parameters
for
Dispensing
Process
The
profile
of
the
system
behavior
is
illustrated
below
(Y
axis
=
amplitude
of
the
tappet)
.
This
diagram
includes
the
following
parameters:
Parameter
Description
Rising
(RI)
This
interval
describes
the
time
required
until
the
valve
is
completely
opened.
It
is
adjustable
in
steps
of
0,01
ms.
Open
Time
(OT)
During
this
phase
the
valve
remains
in
opened
state.
It
is
adjustable
in
steps
of
0,1
ms.
Max.
Open
Time
for
≤
80%
NL
=
3000
ms
Max.
Open
Time
for
>
80%
NL
=
15
ms
CAUTION!
When
working
in
External
mode,
the
cycle
is
initiated
with
the
following
properties:
For
Rising,
Falling,
Delay
and
Needle
Lift,
the
values
determined
before
‐
hand
are
used.
Open
Time
however
remains
active,
until
the
signal
returns
to
state
“Logic
0“
(for
Needle
Lift
≤
80
%)
.
Maximum
Open
Time
for
Needle
Lift
>
80
%
is
restricted
to
15
ms.
Falling
(FA)
The
falling
ramp
of
the
curve
illustrated
above
represents
the
time
re
‐
quired
for
closing
the
valve.
Residual
fluid
meanwhile
is
expulsed
from
the
nozzle
compression
chamber
(the
cavity
at
the
rear
side
of
the
nozzle
in
‐
sert)
.
The
interval
is
adjustable
in
steps
of
0,01
ms.
Delay
(
DL)
This
waiting
phase
between
two
cycles
is
adjustable
in
steps
of
0,1
ms.
CAUTION!
For
valves
operated
with
connected
heating
systems,
a
minimum
delay
of
4,6
ms
is
necessary.
Lower
values
can
only
be
achieved,
if
the
heater
is
operated
with
an
external
control
unit.
Needle
Lift
(NL)
This
parameter
describes
the
stroke
of
the
tappet,
compared
to
its
full
value
of
100
%.
For
the
range
between
80
%
and
100
%,
the
valve
works
in
bipolar
mode.
The
elevated
temperature
in
this
range
reduces
the
average
frequency
and
the
lifetime
of
the
valve.
A
needle
lift
between
70
%
and
80
%
is
the
best
working
range.
Содержание MDS 3000 Series
Страница 1: ......
Страница 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Страница 71: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 71 13 ATTACHMENT 13 1 EC Declaration of Conformity...
Страница 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Страница 73: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 73 13 3 Dimensional Drawing MDV 3200A with MDX 3080 CC...
Страница 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...