9
Jul 2018
54
5.2.2.5
Closing the VR2C Case
Continued…
Check that the
Receiver
Locking Ring is
able to spin
freely.
STEP 8
Return the retaining O-ring
into its groove.
STEP 7
Remove any old
desiccant packs
that may be in the
upper housing and
place a new
desiccant pack into
the upper housing.
STEP 2
Inspect the O-ring surface
on the inside lower portion
of the upper housing
cylinder to be sure it is
clean, undamaged, and
debris free.
STEP 1
Connect the 2-pin
connector from the
lower housing to the
2-pin connector on
the upper housing
wiring harness. This
is power and should
be connected last.
STEP 4
Position the lower and
upper VR2C housings
close together.
Connect the 6-pin
connector from the lower
housing to the 6-pin
connector on the upper
housing wiring harness.
STEP 3