Fault
Cause
Remedy
Error during blow-down:
If blow-down is done incorrectly
or insufficiently, salts may be con-
centrated in the water. Therefore,
foaming can occur in the water,
and water can be carried away
during steam extraction.
Blow down the device every day
according to the operating instruc-
tions.
Boiler sucked up caused by
vacuum build-up.
Blow down.
Fill level detection defective
Replace fill level detection
9.2 Defect, cause, remedy
CAUTION!
The facts and information listed as
defects
in this
chapter are described in such a way that they may
be eliminated by a
person skilled
in
–
Electrics/electronics
–
Mechanics/maintenance
.
The device components mentioned in the “Cause”
column are detailed in the supplied electric circuit
and pneumatic diagrams.
Defect
Cause
Remedy
Water emerging from the drain
hose
Safety valve leaking
Check and adjust, if necessary.
Operating pressure for standard
version: 4 bar, max.
Operating pressure for cleaning
version: 5 bar, max.
Boiler is being overfilled
Electrode dirty
If yes: Remove electrode and
check for soiling (dirt, lime, rust);
clean electrode, if necessary.
Used electrodes need to be
replaced.
Remedy of faults/elimination of defects
Defect, cause, remedy
30.09.2022
Steam generator VEIT SG67