8.
Remove the cover of the cleaning tank and fill VEIT Steam-
Clean (article number 152681) in the cleaning tank observing
the notes indicated on the bottle. The VEIT SteamClean
bottle is secured by means of an aluminium strap which
is pierced using the mandrel inside the cleaning tank. To
enlarge the opening, pierce the strap and rotate the bottle
slightly on the mandrel. Make sure that all of the cleaning
agent has flown into the tank.
WARNING!
–
Do not squeeze the bottle together while
emptying - there is a risk from splashes!
–
Use only one bottle of SteamClean for
each cleaning process!
Then remove the SteamClean bottle and close it again with
its cap. Take care when doing so. Read the notes on the
packaging carefully.
WARNING!
–
Completely empty SteamClean bottles
only may be disposed of with residual
waste. For this, close the bottle again
with its cap.
–
Do NOT RINSE the SteamClean bottle!
NOTICE!
Do NOT YET screw the cover onto the
cleaning tank!
9.
Press the “clean” button to acknowledge that you have filled
VEIT SteamClean into the cleaning tank. SteamClean and
water will be pumped into the boiler. After approximately 3-5
seconds, the pumping process is complete.
NOTICE!
After the pump time has elapsed, screw the
cover onto the cleaning tank.
The active cleaning phase then automatically starts. This
step takes about 20 minutes. LEDs P1, P2 and P3 indicate
the progress of the cleaning cycle. The cleaning cycle is
complete if all the three LEDs are on. The steam generator
then automatically heats up until reaching pressure level P1
(LEDs “P1” and “clean” are flashing).
10.
Two audible and visible signals indicate that pressure level
P1 has been reached. Blow down the steam generator.
Observe the blow-down instructions in chapter
. Press the cleaning button to confirm
blow-down and proper closing of the ball valve.
Maintenance and cleaning
Cleaning program (cleaning version)
30.09.2022
Steam generator VEIT SG67
47